Fireproof Acoustic Downlighters (Cover)

Product 32

32-dlc-ac

Acoustic downlighter cover are designed for areas that require good absorption of airborne and impact sound.

£0.00 ex. Vat

    • 7.1 £

Description

Fireproof acoustic downlighters (cover) fit above suspended ceilings in roof areas, or where floorboards are already in place. Offering effective airborne and impact sound absorption, as well as fire integrity for 60 minutes.

Advantages

– Maintains the fire rating of plasterboard or suspended ceilings rated up to 4 hours
– Available in standard and acoustic forms, preventing sound transfer from different floors of a building up to 63dB
– Can be made to accommodate downlighters alone, or downlighter/transformer combos
– Downlighter cages are a sturdier option, allowing for insulation to be laid over the top after they are fixed in place – ideal for lofts
– Can be used to improve the fire rating of ceiling-mounted speakers as well as downlighters
– The range also contains downlighter adaptors which can convert existing light fittings to fire resistant, low-energy units, saving up to 40W per light whilst providing 66 minutes of fire protection
– Easily installed in 5 minutes or less. Custom sizes made to order.

Application Instructions

Lead the cable from the transformer through the pre-cut downlight aperture in the ceiling
Pierce the cable entry point in the top of the cover with a sharp object, creating an opening large enough to suit the cable size
Feed sufficient cable through the opening for the connection
Compress the cover and pass it through the aperture in the ceiling
Open out the cover once inside the ceiling, away from the light fitting
Using the two supplied pins, fasten opposite inner flanges of the cover to the plasterboard
Insert the light fitting and fasten the closing mechanism over the inner flaps of the downlighter cover to seal the opening
Downlighter covers require a minimum of 40mm horizontal clearance and 15mm vertical clearance
Cages are rigid and require no clearance, meaning that insulation can be packed around them as long as it does not cover the ventilation holes

NB: Downlighter cages cannot be compressed to fit through the light fitting aperture from below and must therefore be positioned from above

Order References / Sizes

 REGULAR                                            LENGTH/WIDTH/HEIGHT (mm)

DLC0                                                     150 x 150 x 120

DLC1                                                     130 x 130 x 070

DLC2                                                     130 x 130 x 100

DLC3                                                     130 x 130 x 140

DLC4                                                     180 x 180 x 130

DLC5                                                     180 x 180 x 170

DLC6                                                     260 x 260 x 120

DLC7                                                     260 x 260 x 230

DLC8                                                     300 x 300 x 170

DLC9                                                     350 x 350 x 230

 

ACOUSTIC                                           DIAM/HEIGHT (mm)

DLC 0/AC                                              150 x 120

DLC 1/AC                                              130 x 070

DLC 2/AC                                              130 x 100

DLC 3/AC                                              130 x 140

DLC 4/AC                                              180 x 130

DLC 5/AC                                              180 x 170

DLC 6/AC                                              260 x 120

DLC 7/AC                                              260 x 230

DLC 8/AC                                              300 x 170

DLC 9/AC                                              350 x 230

If an acoustic cover is required for loft areas, please add /L to the order reference eg: DLC3/AC/L